Power conversion equipment

Hybrid, string and central inverters from 3 kW to 350 kW — supplied with grid-code firmware already loaded for your market, so commissioning does not depend on a field engineer's laptop.

IEC 62109 certified 40+ grid codes pre-loaded IP66 outdoor rated String-level monitoring 10-year warranty
AX-HI series
Residential hybrid · 3 – 12 kW

Single and three-phase units with battery-ready DC coupling and backup supply in under 10 ms.

AX-SI series
Commercial string · 15 – 125 kW

Up to 9 MPPT inputs, string-level monitoring and AC-coupled retrofit without replacing the existing array.

AX-CI series
Central station · 250 – 350 kW

1,500 V DC input with liquid cooling for utility plants; typically paired with our 5 MWh storage blocks.

Model specifications

Specification by series

Select a series to view its model matrix. Intermediate power classes are available in each range — request the full datasheet for the complete list.

AX-HI series — residential hybrid inverters
ParameterAX-HI-5KAX-HI-8KAX-HI-10KAX-HI-12K
Rated AC output5 kW8 kW10 kW12 kW
Phase configurationSingle phase 230 VThree phase 400 V
Max. PV input power7.5 kWp12 kWp15 kWp18 kWp
MPPT inputs2233
Max. DC input voltage1,100 V DC
MPPT voltage range160 – 950 V (full power at 300 V)
Battery voltage range80 – 450 V DC
Max. charge / discharge current60 A120 A135 A135 A
Backup transfer time< 10 ms (UPS-class, dedicated backup port)
Max. efficiency97.8 %
Protection ratingIP65 · integrated Type II DC & AC SPD
Dimensions / weight520 × 430 × 200 mm · 26 kg
CommunicationRS485 · Wi-Fi · 4G optional · Modbus TCP
Warranty10 years (extendable to 15)

Efficiency values measured per IEC 61683 and EN 50530. All models ship with the grid-protection parameters of the destination country already commissioned; remote firmware update is supported for the full operating life.

Engineering detail

What makes commissioning painless

Grid code loaded at the factory

We ship against your nominated country and utility, with the correct protection settings and certificate pre-installed. Importing an inverter and then discovering the grid code is wrong costs weeks — this eliminates that failure mode.

String-level diagnostics

Every MPPT channel reports voltage, current and insulation resistance individually. A shaded or failed string is identified remotely instead of through a site visit — typically the single largest O&M saving.

Built for the environment it ships to

Marine-grade C5 coating options, IP66 enclosures and wide temperature derating curves for coastal, desert and high-altitude sites. We publish the derating table rather than hiding it.

Spares and service agreements

Critical spares kits held at our Rotterdam, Houston and Dubai warehouses. Extended service contracts with 48-hour replacement guarantee for utility and C&I portfolios.

Grid compliance

Certified for the markets we ship to

Below is a partial list of the grid codes embedded in our standard firmware. If your market is not listed, send us the interconnection requirement and we will confirm feasibility within five working days.

EN 50549-1 / -2 VDE-AR-N 4105 VDE-AR-N 4110 / 4120 CEI 0-21 UNE 217002 AS/NZS 4777.2 UL 1741 SA / SB IEEE 1547-2018 G98 / G99 NRS 097-2-1 IEC 61727 MEA / PEA Thailand C10/11 Belgium OVE R25 Austria NC RfG (EU) 2016/631
Next step

Confirm a model and get landed pricing

Send us the array size, grid connection point and target market. We return a matched inverter model, its certificate list and FOB/CIF pricing.